Radiant Tracer RTX-2400
Hazardous Location Ratings
Class 1 Division I and II Group D Hazardous Location
CSA T - Code - T2C Ambient 40° This System Equipped for High Altitude.
For indoor / Outdoor Use.
Description
RTX-2400 Series is designed to install on existing catalytic heaters; quick and easy! Designed to heat trace prodcution lines, fuel gas, flare, venting, water lines and many other applications to a distance of 800' to 1000' ft of tracing. Pump is designed to exhaust vented gas up to 40 PSI which can be utiliaed as another sources of fuel gas or flare system as purge gas with proper installation.
System Components
Radiant Tracer Model RTX-2400 Series Heat Tracing System
Heat Tracing System , High Temperature Shut Down Controller , Temperature Gauges , All Connection Fittings
* Circulating Pump Sold Separately
Manufactured with CSA approved components
Catalytic Adaptation Sizes |
2424 - Catalytic Heater |
Heat Tracer Distance |
800' to 1,000' ft |
Temperature Control Range |
(50-104°F) 10 - 40°C |
High Temperature Shutdown Setting |
176°F / 80°C |
Recommended Fluid |
Norkool Antifreeze |
System Fluid Capacity |
7.5 Gals |
BTU Input |
20,000 BTU per/ hr |
Heat Tracing Requirement |
½" Stainless tubing |