Radiant Tracer RTX-2400B-GR (Gas Recovery Eco-System)

 RTX B GR Series Model Pic 1 web

 aztec logo

 

Hazardous Location Ratings
Class 1 Division I and II Group D Hazardous Location
CSA T - Code - T2C Ambient 40° This System Equipped for High Altitude.
For indoor / Outdoor Use.

Description:

RTX-2400B-GR series model is designed to heat trace production lines, fuel gas, flare, vent water lines and many various applications to a distance of 800' to 1000' ft. of tracing.

This system is retrofitted with a unique pump exhaust gas recovery system that captures the vented gas and introduces the gas back into fuel gas supply system. Eliminating or drastically reducing vented gas emissions, while preventing hindrance freezing issues that affect production downtime. 

System Components

Complete Unit Box

  • 1 - Utility Box (4' X 4' X 2) with Secondary Containment.
  • 1 - 24 X 24 Catalytic Heater ( CSA, NAT Gas, 20,000 BTU Rating )
  • 1 - Radiant Tracer Model RTX-2400 Series Heat Tracing System
  • 1 - ½" Wilden / Sandpiper Diaphragm Circulating Pump & Rytech Gas Recovery System
  • 1 - Temperature Controller
  • 1 - High-Temperature Shutdown Controller All regulators, inlet gas filtration, temperature gauges, fuel inlet gas valve, and all connection settings.

  Manufactured with CSA approved components. 

Heat Tracer Distance

800' to 1,000' ft

Temperature Control Range

(50-104°F) 10 - 40°C

High-Temperature Shutdown Setting

176°F / 80°C

Recommended Fluid

Norkool Antifreeze
Ucartherm Antifreeze

System Fluid Capacity

7.5 Gals

BTU Input

20,000 BTU per / hr

Heat Tracing Requirement

½" Stainless tubing
½" Polyethylene tubing (60 - 70 °C).
½" PB Series Rubber Hose
½" PFA Series PFA Tubing

Fuel Type Models Available Natural Gas / LPG
Fuel Usage 0.01-0 e3m3/d @ 1 gallon/minute 35 psi supply pressure.
Pressure Ratings Fluid 14 PSI inlet/ 100 PSI outlet
Fuel Gas Supply: 150 PSI

Documents